POWER THE DRAIN WATER FILTER TANK

Install a Power Plug

The Drain Water Filter Tank is shipped without a power plug.

OMAX recommends connecting an industrial grade pin and sleeve plug that meets the following criteria:

  • 16 A, 250 VAC, 2-pole, 3-wire, IP44 or better
  • Has a first-make last-break protective bonding contact (earthing contact)
  • Suitably rated in accordance with EN 60309-1, -2 or IEC 60309-1, -2
  • Suitably rated for its intended use and complies with local, regional, or national electrical codes

An example of a suitable plug and a matching outlet is shown below.

 

Figure 10  

Warning

Electrical wiring connections should be performed by qualified personnel only and in accordance with local, regional, or national electrical codes.

Power On the Drain Water Filter Tank

Insert the power plug to an electrical outlet.

Caution

Ensure the equipment is properly grounded in accordance with national, state, and local codes. Never remove any prong from the plug. Always plug into the proper electrical outlet. Improper connection can result in a risk of electrical shock. If the electrical outlet is NOT properly grounded, or if in doubt as to whether the tool is properly grounded, contact a qualified electrician or service personnel.