Remove the Slat Bed Assembly

caution

Bacteria in the tank water can build up. A minor break in the skin can introduce harmful bacteria into a wound. Always wear protective gloves if you have cuts or open wounds on your hands. Wear gloves that provide protection against sharp metal edges.

1. Open the lid and lock it in the upright position.
caution

Use care when opening or closing the lid to avoid injury. Never let the lid free-fall. Keep hand, fingers, and body parts away from the side of the table when closing the lid.

2. Remove the garnet bins.

Figure 2  

3. Loosen the cutting bed bolts [1] and align the t-nuts [2] with the frame slot [3].

Figure 3  

notice

Use care when removing the cutting bed to avoid damage to the Y- and Z-axes and the nozzle assembly.

4. Carefully lift the cutting bed out of the catcher tank.

Figure 4  

5. Clean the frame t-slot [1] by spray with a strong stream of water.

Figure 5