a. | Open the lid and lock it in the upright position. |
Use care when opening or closing the lid to avoid injury. Never let the lid free-fall. Keep hand, fingers, or body parts away from the side of the table when closing the lid.
Figure 938
Make sure the abrasive feed tube is not connected to the nozzle.
Figure 939
b. | Position the nozzle in the center of the tank, between two slats. |
Figure 940
c. | Close the lid. |
Use care when opening or closing the lid to avoid injury. Never let the lid free-fall. Keep hand, fingers, or body parts away from the side of the table when closing the lid.
d. | Click Test [1]. |
Figure 941
e. | In Test Operations, select Test Cutting Head (Pump, Jet, and Abrasive), and click Next. |
Figure 942
f. | Click Start Test. |
Figure 943
g. | Click Close when the test is complete. |
2. | Conduct a nozzle test with abrasive. |
a. | Insert the abrasive feed tube into the garnet abrasive inlet [1]. |
Figure 944
b. | Click Test [1]. |
Figure 945
c. | In Test Operations, select Test Cutting Head (Pump, Jet, and Abrasive), and click Next. |
Figure 946
d. | Click Start Test. |
Figure 947
e. | Observe the garnet abrasive tube [1] to make sure that the abrasive is flowing. |
Figure 948
f. | Click Close when the test is complete. |
The nozzle test automatically stops and closes the Test in progress window after 60 seconds.